| Specifications of the MS8209 5 in 1 meter | ||||
|---|---|---|---|---|
| As a multimeter | ||||
| DC Voltage | ||||
| Range | Resolution | Accuracy | ||
| 400mV | 0.1mV | ± (0.7% of reading + 2 digits) | ||
| 4V | 1mV | ± (0.7% of reading + 2 digits) | ||
| 40V | 10mV | ± (0.7% of reading + 2 digits) | ||
| 400V | 100mV | ±(0.7% of reading + 2 digits) | ||
| 600V | 1V | ± (0.7% of reading + 2 digits) | ||
| Input impedance: 10 M Ohm | ||||
| Over load protection: 400mV Range 250V DC or rms AC, 4V-6 00V ranges: 600V DC or rms AV, Max input voltage : 600V DC or rms AC | ||||
| AC Voltage | ||||
| Range | Resolution | Accuracy | ||
| 4V | 1mV | ± | ||
| 40V | 10mV | ±(0.8% of reading + 3digits) | ||
| 400V | 100mV | ± (0.8% of reading + 3 digits) | ||
| 600V | 1V | ± (0.8% of reading + 3 digits) | ||
| Input impedance: 10 MOhm | ||||
| Over load protection: 400mV Range 250V DC or rms AC, 4V-6 00V ranges: 600V DC or rms AV, Max input voltage : 600V DC or rms AC | ||||
| Frequency range: 40 to 1000Hz, | ||||
| Response: Average, calibrated in rms of sine wave. | ||||
| DC Current | ||||
| Range | Resolution | Accuracy | ||
| 40mA | 10uA | ± (1.2% of reading + 3 digits) | ||
| 400mA | 100uA | |||
| 10A | 10mA | ± (3.0% of reading + 10 digits) | ||
| mA ranges: F500mA/250V fuse (quick acting),10A range: unfused. Max. Input current:mA jack:400mA,10A jack :10A; Voltage Drop: ma ranges :5mV/1mA, 10A range: 10mV/1A | ||||
| AC Current | ||||
| Range | Resolution | Accuracy | ||
| 40mA | 10uA | ± (1.5% of reading + 5 digits) | ||
| 400mA | 100uA | |||
| 10A | 10mA | ± (3.0% of reading + 10 digits) | ||
| mA ranges: F500mA/250V fuse (quick acting),10A range: unfused. Max. Input current:mA jack:400mA,10A jack :10A; Voltage Drop: ma ranges :5mV/1mA, 10A range: 10mV/1A | ||||
| Response: Average, calibrated in rms of sine wave. | ||||
| Resistance | ||||
| Range | Resolution | Accuracy | ||
| 400 >Ω | 0.1>Ω | ± (1.2% of reading + 2 digits) | ||
| >4KΩ | 1>Ω | |||
| 40K>Ω | 10>Ω | |||
| 400K>Ω | 100>Ω | |||
| 4M>Ω | 1K>Ω | |||
| 40M>Ω | 10>Ω | ±(1.2% of reading + 2 digits) | ||
| Open Circuit Voltage:0.25V, Overload Protection: 250V or rms AC | ||||
| Capacitance | ||||
| Range | Resolution | Accuracy | ||
| 4nF | 1pF | ± (3.0% of reading + 3 digits) | ||
| 40nF | 10pF | |||
| 400nF | 0.1nF | |||
| 4uF | 1nF | |||
| 40uF | 10nF | |||
| 200uF | 100nF | |||
| Overload Protection: 250V DC or rms AC | ||||
| Frequency | ||||
| Range | Resolution | Accuracy | ||
| 9.999 Hz | 0.001Hz | ± (2.0% of reading + 5 digits) | ||
| 99.99Hz | 0.01 Hz | ± (1.5% of reading + 5 digits) | ||
| 999.9 Hz | 0.1Hz | |||
| 9.999 KHz | 1 Hz | |||
| 99.99 KHz | 10 Hz | ± (2.0% of reading + 5 digits) | ||
| 199.9 KHz | 100 Hz | |||
| >200 KHz | . | Reference only | ||
| By Hz Range: Range: 0 - 200 KHz Input Voltage: 0.5V - 10V rms AC By V Range: Range: 0 - 40 KHz Input Voltage range: 0.5V - 600V rms AC, Input impedance: 10M>Ω >By mA Range: >Range: 0 -40 KHz, Input current range: 100mA- 400mA rms AC | ||||
| Duty Cycle | ||||
| Range | Resolution | Accuracy | ||
| 0.1 - 99.9 % | 0.1% | ± 3.0% | ||
| Note: When measuring frequency, the range by Duty of Hz range is larger than by Duty of voltage ot current range. More to see on the manual book. | ||||
| Diode | ||||
| Range | Resolution | Accuracy | ||
| Diode drop | 1mV | Display: read appromix forward voltage of diode | ||
| Continuity | ||||
| Built in buzzer will sound if the resistance is lower than 40 Ohms. | ||||
| As a Thermometer | ||||
| Range | Resolution | Accuracy | ||
| 0.1>°C | >0.1°C | -20>° to 0 ° | ± (5.0% of reading + 8 digits) | |
| 0>°C to 20 °C | ±(3.0% of reading + 8 digits) | |||
| 20 >°C to 400°C | ± (2.0% of reading + 5 digits) | |||
| >0.1°C | 1 >°C | -20>°C to 0°C | ±(5.0% of reading + 5 digits) | |
| 0>°C to 400°C | ±(1.0% of reading + 3 digits) | |||
| 400>°C to 1000°C | ±(2.0% of reading + 3 digits) | |||
| As a Humidity Meter | ||||
| Range | Resolution | Accuracy | ||
| 30 - 90 % | 0.1% | ± 5.0% RH | ||
| Response time: 45% - 90 %RH < 10 Minutes, 90% - 45% < 15 Minutes | ||||
| As a Sound Level Meter | ||||
| Range | Resolution | Accuracy | ||
| 30dB - 100dB | 0.1dB | ± 3.5% dB at 94 dB, 1K Hz sine wave. | ||
| Range | Resolution | Accuracy | ||
| Lux ( 4000) | 1 Lux | ± (5.0% of reading + 10 digits) at color temp. 2850K, calibrated to standard incandescent lamp at color temperature 2856 K | ||
| X 10 Lux ( 40000) | 10 Lux | |||